Biot Number Calculator
Enter h, Lc, and k to compute the Biot number.

Understanding the Biot Number

The Biot number, denoted as Bi, is a dimensionless quantity that arises in the study of transient heat conduction. It compares the conductive resistance within a solid body to the convective resistance at its surface. In essence, Bi tells us whether temperature gradients inside a body are significant compared to those at the boundary. If internal conduction is much faster than surface convection, the body behaves almost uniformly in temperature, a situation well approximated by the lumped capacitance method. When surface convection competes with or surpasses internal conduction, pronounced temperature gradients develop inside the object and more detailed spatial analysis is required. The Biot number provides a convenient yardstick for this comparison.

The number is defined by the ratio:

Bi = h Lc k

where h is the convective heat-transfer coefficient, Lc is a characteristic length, and k is the thermal conductivity of the solid. The characteristic length is defined as the volume of the object divided by its surface area, Lc = VA. This choice gives a length scale representative of heat flow from the interior to the surface. For a long cylinder of radius r, for example, Lc = r}{2}. The Biot number therefore captures geometry, material properties, and the surrounding fluid's ability to remove heat.

Implications for Transient Conduction

In transient thermal problems we often seek to simplify the governing heat equation by assuming a uniform temperature within the solid. This lumped capacitance approach treats the body as a single thermal node with heat storage capacity proportional to its mass and specific heat. The method yields an exponential cooling or heating curve with a time constant \tau = \frac{\rho c V}{h A}. However, the approximation is only valid when the Biot number is small, typically Bi < 0.1. In this regime, internal conduction is efficient enough to keep the temperature nearly uniform, so the single-node model captures the dominant physics. When Bi exceeds 0.1, significant gradients develop and one must solve the transient heat equation using spatially resolved methods such as separation of variables or numerical simulation.

The distinction is not merely academic. Consider cooling a steel sphere in air. Steel has a high thermal conductivity, and air's convection coefficient for natural convection is modest, around 10 W/m²K. For a small sphere with radius 1 cm, Lc = \frac{r}{3} = 0.0033 \text{ m}, and with k ≈ 45 \text{ W/mK}, the Biot number is roughly 0.007, well within the lumped regime. We may therefore model its cooling with a simple exponential expression. In contrast, a wooden beam of similar size but low conductivity (k ≈ 0.12 \text{ W/mK}) yields Bi ≈ 0.27, violating the lumped assumption and necessitating a more sophisticated analysis.

Deriving the Biot Number

The Biot number emerges naturally when nondimensionalizing the transient heat conduction equation. Starting from Fourier's law and energy conservation, the three-dimensional heat equation is \rho c \frac{\partial T}{\partial t} = k \nabla^2 T. Introducing dimensionless variables \theta = \frac{T - T_\infty}{T_i - T_\infty} and \mathbf{x}^* = \frac{\mathbf{x}}{L_c}, and scaling time by \tau = \frac{\rho c L_c^2}{k}, the equation becomes \frac{\partial \theta}{\partial t^*} = \nabla^{*2} \theta. At the boundary, a convection condition couples the solid to the fluid: -k \frac{\partial T}{\partial n} = h (T - T_\infty). Expressing this in dimensionless form introduces the ratio \frac{h L_c}{k}, which is exactly Bi. Thus, Bi quantifies the relative strength of convection to conduction when solving the dimensionless equation.

Applications and Limitations

Engineers and scientists evaluate the Biot number when designing heat treatment processes, assessing cooling of electronic components, or modeling the thermal response of foods and biological tissues. A small Biot number simplifies design calculations and often indicates more uniform material properties. Conversely, a large Biot number warns that internal hot spots or cold spots may develop. It is important to remember that Bi depends on the convection coefficient, which can vary widely with flow conditions. A component that satisfies the lumped criterion in still air may violate it in a high-speed forced convection environment because h increases significantly.

While the conventional threshold Bi < 0.1 is widely cited, it is not a strict boundary. Numerical studies show that acceptable accuracy may extend to Bi ≈ 0.2 for geometries with mild gradients, whereas even smaller Biot numbers may be insufficient for highly sensitive applications. The key is that the Biot number guides our judgment: if the value is small, we may confidently adopt a lumped model; if it is large, we must consider spatial effects.

Example Values

The table below lists sample Biot numbers for a 2 cm cube cooled by air with h = 15 \text{ W/m²K}. The characteristic length for a cube is half the side length, so Lc = 0.01 \text{ m}. Plugging different conductivities into the Biot formula illustrates how material choice influences the outcome.

Materialk (W/mK)BiImplication
Aluminum2050.0007Lumped model excellent
Glass1.00.15Spatial gradients important
Epoxy0.20.75Lumped model invalid
Wood0.121.25Strong internal gradients

Using the Calculator

To employ this tool, supply the convection coefficient, characteristic length, and material conductivity. The calculator multiplies h and Lc, divides by k, and displays the Biot number along with a qualitative judgment. Values below 0.1 will trigger a message that the lumped capacitance method is valid, whereas higher values warn of significant internal gradients. By adjusting the inputs, you can explore how geometric scaling or material substitution affects thermal response. This is particularly valuable when designing electronic components where minimizing thermal gradients can prevent failure.

In summary, the Biot number encapsulates the competition between surface convection and internal conduction. Its evaluation is the first step in any transient heat-transfer analysis and informs the level of modeling detail required. Small Biot numbers grant the engineer the luxury of simple lumped models; large Biot numbers necessitate more sophisticated solutions. Understanding and calculating this dimensionless quantity is therefore fundamental in thermal science.

Related Calculators

Virus Mutation Rate Calculator - Track Genetic Drift

Estimate how many virus copies accumulate mutations across generations given a replication factor and mutation rate.

virus mutation calculator virology tool

Floor Joist Span Calculator - Wood Framing Design

Estimate the maximum allowable span of a wood floor joist based on size, spacing, species properties, and applied loading using bending and deflection checks.

Stefan-Boltzmann Law Calculator - Radiative Power

Calculate radiant heat emission using the Stefan-Boltzmann law. Determine power based on temperature, surface area, and emissivity.

Stefan Boltzmann calculator blackbody radiation thermal emission