Ethernet Cable Attenuation Calculator

JJ Ben-Joseph headshot JJ Ben-Joseph

Cable Specifications
Signal Parameters
Enter cable specifications to calculate signal attenuation and maximum distance.

Ethernet Cable Attenuation and the Distance Limit Problem

Ethernet signals transmitted over copper cables gradually weaken as electrical energy is dissipated through resistance and dielectric losses. Attenuation—the loss of signal strength—increases with cable length and frequency. A 1 Gbps signal at high frequency experiences more attenuation per meter than a 100 Mbps signal at low frequency. Understanding attenuation is critical when planning network installations: too much attenuation causes data corruption, retransmissions, and eventual link failure. Network administrators and installers must calculate whether a proposed cable run will attenuate the signal below acceptable thresholds, or if repeaters, switches, or fiber-optic alternatives are necessary.

The Ethernet standard (IEEE 802.3) specifies maximum attenuation allowed per cable category and frequency. For example, Cat5e is rated for 100 MHz with a maximum of ~2 dB loss per 100 meters; Cat6a can support higher frequencies with lower attenuation. This calculator predicts attenuation for given cable specifications, helping plan network infrastructure.

Attenuation Formula and Cable Loss Characteristics

Attenuation in copper cables follows an empirical model based on cable resistance and dielectric loss:

Attenuation (dB) = L × [ A + B f ]

where L is cable length (meters), f is frequency (MHz), and A and B are constants specific to the cable category (higher B values mean greater frequency dependence). Attenuation increases with both length (linear) and square root of frequency (super-linear at higher frequencies). Cat5e at 100 meters and 100 MHz attenuates ~2 dB; the same cable at 250 meters attenuates ~5 dB; at 1 GHz, the same 100-meter run attenuates ~20+ dB.

Worked Example: Planning a 100-Meter Cat5e Run

A network installation requires running Cat5e Ethernet from a switch to an office 100 meters away. The link will carry 1 Gbps traffic, but Cat5e is rated for 100 MHz. Assess feasibility:

Step 1: Identify cable attenuation at operating frequency – Cat5e at 100 meters and typical 1 GHz (gigabit): Using empirical data, ~20+ dB loss.

Step 2: Check acceptable thresholds – Gigabit Ethernet receivers typically tolerate 12–15 dB attenuation before error-free reception becomes impossible.

Step 3: Assess feasibility – 20+ dB loss > 15 dB maximum. This run is MARGINAL to IMPOSSIBLE. The link may work sporadically or not at all.

Recommendation: Use Cat6 or Cat6a (lower attenuation), or install a switch/repeater at ~50 meters to split the run into two shorter segments, each with acceptable attenuation.

Attenuation by Cable Category and Frequency

Cable Category Rated Frequency 100m @ Rated Freq 100m @ 1 GHz Max Distance (6 dB limit) Typical Use
Cat5e 100 MHz ~2 dB ~20+ dB ~50 m 100 Mbps or 1 Gbps short runs
Cat6 250 MHz ~3 dB ~14 dB ~70 m 1–10 Gbps, moderate distances
Cat6a 500 MHz ~4 dB ~10 dB ~100 m 10 Gbps, longer distances
Cat7 600 MHz ~4.5 dB ~9 dB ~120 m 100 Gbps (emerging)
Cat8 2000 MHz ~7 dB ~8 dB ~150+ m Future-proofing (rare deployment)

The table shows why Cat6a and Cat7 are preferred for longer runs or higher speeds: they support longer distances with acceptable attenuation at high frequencies. Cat5e, while cheap, is marginal for anything beyond ~50 meters at gigabit speeds.

Mitigating Attenuation

Several approaches reduce attenuation problems: (1) Use thicker, higher-quality cable (lower resistance). (2) Use higher-category cable (Cat6a, Cat7) rated for better frequency response. (3) Keep runs shorter by placing switches/repeaters strategically. (4) Use fiber-optic cables for very long distances (attenuation is negligible over kilometers). (5) Upgrade network hardware (better receivers, error correction) to tolerate slightly higher attenuation. For most practical installations, Cat6 is a good compromise: cheap, widely available, and suitable for distances up to 70–100 meters at modern gigabit speeds.

Using the Calculator

Enter your cable category (Cat5e through Cat8), the length of the run in meters, and the frequency at which you'll operate. The calculator computes the expected attenuation in dB and compares it to typical acceptable thresholds. If attenuation exceeds acceptable limits, the result indicates the run may fail or require mitigation (upgrading cable, shortening the run, or inserting repeaters).

Limitations and Real-World Factors

This calculator provides theoretical attenuation based on ideal cables. Real-world factors affect results: poor-quality cable, improper termination, temperature variation, and EMI all increase attenuation beyond theory. Cables installed in conduit, bundled tightly, or exposed to heat may perform worse. Reputable cable manufacturers publish detailed attenuation specifications; compare calculated results against manufacturer data for your specific cable. Additionally, this calculator does not account for echo losses, return loss, or velocity factor—advanced considerations for high-speed links (10 Gbps+). For critical installations, hire a certified network installer to measure actual attenuation with proper equipment.